The FTE-1800Q is an electromagnetic flowmeter for conductive liquids in hygienic process lines. It is intended for media with conductivity of at least 5 µS/cm. Alongside volumetric flow, it monitors media temperature, conductivity, totals and diagnostic status.
Switch, pulse, 4–20 mA and RS485 signals support integration with process control systems. Applications include batch filling, ratio mixing, CIP solution monitoring and pump protection. Confirm the wetted materials and process connection against the actual medium before ordering.
| Nominal diameter | DN15–DN50 |
|---|---|
| Suitable media | Conductive food and beverage liquids such as beer, milk, juice, soft drinks, tomato sauce, yoghurt, cream and ice cream; conductivity ≥ 5 µS/cm |
| Unsuitable media | Gas, steam, oil and non-conductive liquids below 5 µS/cm |
| Flow range | 1–100 L/min; 0.06–6 m³/h; 0.26–26.41 gpm |
| Flow velocity | 0.31–30.94 ft/s, as stated in the source specification; confirm the applicable size and range for selection |
| Installation | Full pipe required; ground the sensor and pipe; avoid strong electromagnetic interference and vibration |
| Medium temperature | −20 to 150 °C (−4 to 302 °F) |
| Pressure resistance | 40 bar / 580.1 psi / 4 MPa |
| Electrode material | Stainless steel 1.4435 / 316L |
| Liner | Food-grade PFA |
| Temperature measurement | −20 to 150 °C (−4 to 302 °F) |
| Conductivity measurement | 100–100,000 µS/cm |
| Outputs | Switch, pulse, 4–20 mA analog and RS485 |
| Supply voltage | 18–32 V DC |
| Process connection | Hygienic flange |
| Ambient temperature | −20 to 65 °C (−4 to 149 °F) |
| Storage temperature | −20 to 80 °C (−4 to 176 °F) |

Tell us about your measurement task and we will help with product selection and technical questions.info@doweston.com