Home > Products > Flow Measurement > Ultrasonic Flow Meter > FTUM-2600 Clamp-on Ultrasonic Flowmeter

FTUM-2600 Clamp-on Ultrasonic Flowmeter

Measure liquid flow without interrupting the pipeline The FTUM-2600 is a compact clamp-on ul...
  • Factory Direct
    Chengdu production base, every unit calibrated before shipping
  • Fast Delivery
    Standard models in stock, custom builds on schedule
  • Technical Support
    Selection guidance / installation and commissioning / after-sales support
Brand: DOWESTONWarranty: 12 monthsOEM / customization supported

Product Overview

OVERVIEW

Measure liquid flow without interrupting the pipeline

The FTUM-2600 is a compact clamp-on ultrasonic liquid flowmeter using the transit-time principle. Its sensors mount on the outside of the pipe, so the liquid does not contact the sensors and the pipe need not be cut for installation. It measures volumetric flow and totals for compatible clean liquids.

The instrument provides local display and setup, 4–20 mA output and Modbus/RTU communication for PLCs, data acquisition and monitoring systems. Confirm pipe material, diameter, wall condition and acoustic properties when selecting the installation.

Features

FEATURES
  • External clamp-on sensors provide non-contact measurement without opening the pipe.
  • No moving parts, reducing mechanical wear and maintenance.
  • Transit-time measurement calculates velocity from upstream/downstream travel-time difference.
  • Compact integrated design for limited installation space.
  • Local display and setup; 4–20 mA and Modbus/RTU outputs.
  • Daily, monthly and annual total-flow records.
  • Compatible with suitable carbon-steel, stainless-steel, copper, PVC, PP and PU pipes.

Specifications

SPECIFICATIONS
Velocity range0.05–5.0 m/s
Accuracy1.5% of reading + 0.2% of full scale over 0.5–5.0 m/s, per source
Repeatability0.80% of reading
Turndown10:1
Response time< 2 s
Pipe sizeDN10–DN40
Analog output4–20 mA
CommunicationRS232/RS485 Modbus RTU
Power supply20–28 V DC
DisplayColor TFT, per source specification
Medium/ambient temperature0–50 °C
Ambient humidity< 95% RH
TransmitterAluminum alloy, IP65
Sensor materialPEI
Main unit dimensions48 mm wide; 115 mm front-body height; 125 mm overall height, per source drawing
External clamp sensor64.0 × 34.0 × 30.0 mm, per source drawing

Clamp bracket dimensions (mm)

PipeABCD range
DN1028.5105813.5–16.5
DN1528.5105816.5–23
DN2026.5155825–28
DN2530185832–35
DN323322.56838–45
DN4038277848–54

Downloads

DOWNLOADS
  • Brochures
  • User Manuals
  • Drawings and Software
Our experts are ready to help Wherever you are, DOWESTON's experienced engineering team is ready to support your product selection and applications - contact us today!
Contact Us→

Copyright © 2019-2026 Doweston. All rights reserved.

Copyright © 2019-2026 Doweston. All rights reserved.
DOWESTON
Back to main page
Privacy settings Privacy settings