The FTE-1800B measures volumetric flow of conductive liquids in water supply and drainage, chemical processing, metallurgy and mining. Its inline electromagnetic sensor and signal converter are installed separately. The sensor detects an induced voltage proportional to liquid velocity; the converter processes, displays and outputs the measurement.
The remote arrangement lets the measuring point and operator or control-system connection be positioned independently. Select the liner, electrodes, process connection, pressure and temperature ratings, and protection grade for the actual medium and site conditions.
| Nominal diameter | DN3–DN3000 |
|---|---|
| Maximum flow velocity | 15 m/s |
| Accuracy class | DN3: 1.0; DN15–DN600: 0.3 with ±3 mm/s below 1 m/s; DN6–DN10 and DN700–DN3000: 0.5 with ±4 mm/s below 0.8 m/s |
| Minimum liquid conductivity | ≥ 5 µS/cm |
| Nominal pressure | 0.6–6.3 MPa; special versions on request |
| Medium temperature | Depends on the selected wetted materials |
| Signal and grounding electrodes | 316L stainless steel, Hastelloy C/B, titanium, tantalum, platinum-iridium alloy or tungsten-carbide-coated stainless steel |
| Liner materials | PTFE, chloroprene rubber, polyurethane, FEP (F46) or reinforced PFA |
| Electrode cleaning mechanism | DN250–DN3000 |
| Outputs | Switch, pulse, 4–20 mA analog and RS485 |
| Process connection | Flange; carbon-steel or stainless-steel connection flange |
| Ambient temperature | −25 to 60 °C |
| Protection grade | IP65, IP67 or IP68, depending on configuration |
| Sensor-converter cable | Normally up to 100 m; longer runs require a special order |

Tell us about your measurement task and we will help with product selection and technical questions.info@doweston.com