■ Measuring media: dry gas, gas, liquid, slightly corrosive liquid, viscous liquid
■ Measuring range :-0.1-0.35MPa-100MPa
■ Comprehensive accuracy :±0.25%FS
■ Diaphragm material: Stainless steel 316L
■ Operating temperature :-35-120℃
■ Output: 4-20mA, RS485, Hart, etc
■ Process connection: chuck, clamp, thread, flange
■ Warranty: Limited warranty for up to 3 years
■ Electrical connection: aviation plug (IP65), waterproof gran (IP68)
■ Sealing: silicone, fluorine rubber·
| Applicable media | Dry gases, gases, liquids that require sanitary requirements |
| measurement range | -0.1-100MPa |
| Comprehensive accuracy | ±0.25%FS |
| Repeat accuracy | ≤± 0.1%FS/year |
| Zero temperature drift | ±0.02FS/℃ |
| Input voltage | 12-36V DC |
| Output | 4-20mA、0-5V、0-10V,etc. |
| Working temperature | -40-120℃ |
| Overload pressure | 150%FS |
| bursting pressure | 200%FS |
| ambient temperature |
-40-80℃ |
| Response time | <3-10ms (10...90%FS) |
| Seismic resistance | ±20g 20-5000Hz |
| Life time | >1*10^8 pressure cycles |
| Liquid contact material | Stainless Steel 316L |
| Surface roughness | Ra≤0.4μm |
| Shell Material | Stainless |
| Protection level | Electrical part IP65 |
| Electrical connection | Aviation plug (IP65), waterproof Gran (IP68) |
| Electrical Protection | Overload/Reverse Phase Protection |
| Sealing | Silicone, fluorine rubber |
| Installation method | Chuck, clamp, thread |
| Weighs | About 1.4kg |