                                ■ Measuring media: dry gas, gas, liquid, slightly corrosive liquid, viscous liquid
■ Measuring range :-0.1-0.35MPa-100MPa
■ Comprehensive accuracy :±0.25%FS
■ Diaphragm material: Stainless steel 316L
■ Operating temperature :-35-120℃
■ Output: 4-20mA, RS485, Hart, etc
■ Process connection: chuck, clamp, thread, flange
■ Warranty: Limited warranty for up to 3 years
■ Electrical connection: aviation plug (IP65), waterproof gran (IP68)
■ Sealing: silicone, fluorine rubber·
| Applicable media | Dry gases, gases, liquids that require sanitary requirements | 
| measurement range | -0.1-100MPa | 
| Comprehensive accuracy | ±0.25%FS | 
| Repeat accuracy | ≤± 0.1%FS/year | 
| Zero temperature drift | ±0.02FS/℃ | 
| Input voltage | 12-36V DC | 
| Output | 4-20mA、0-5V、0-10V,etc. | 
| Working temperature | -40-120℃ | 
| Overload pressure | 150%FS | 
| bursting pressure | 200%FS | 
| ambient temperature | -40-80℃ | 
| Response time | <3-10ms (10...90%FS) | 
| Seismic resistance | ±20g 20-5000Hz | 
| Life time | >1*10^8 pressure cycles | 
| Liquid contact material | Stainless Steel 316L | 
| Surface roughness | Ra≤0.4μm | 
| Shell Material | Stainless | 
| Protection level | Electrical part IP65 | 
| Electrical connection | Aviation plug (IP65), waterproof Gran (IP68) | 
| Electrical Protection | Overload/Reverse Phase Protection | 
| Sealing | Silicone, fluorine rubber | 
| Installation method | Chuck, clamp, thread | 
| Weighs | About 1.4kg |