| Applicable media | Dry gas, gas, liquid, slightly corrosive liquid, viscous liquid |
| Measurement range | -0.1-70MPa |
| Comprehensive precision | ± 0.25%FS |
| Repeat Precision | ≤± 0.1%FS/year |
| Zero temperature drift | ±0.02FS/℃ |
| Input voltage | 12-36V DC |
| Output | 4-20mA, 0-5V, 0-10V, etc. |
| Working temperature | -35-80℃ |
| Overload pressure | 150%FS |
| Bursting pressure | 200%FS |
| Ambient temperature |
-35-60℃ |
| Response time | <3-10ms (10...90%FS) |
| Vibration resistance | ±20g 20-5000Hz |
| Lifetime | >1*10^8 pressure cycles |
| Liquid texture | Ceramics (Al2O3 96%) |
| Shell Material | 304 stainless steel |
| Protection level | Electrical part IP65 (optional IP68) |
| Electrical connection | Terminal, Hoffmann connector |
| Electrical Protection | Overload/Reverse Phase Protection |
| Seal | FKM (fluorine rubber) |
| Installation method | thread, flange |
| Weight | about 0.4kg |