--Comprehensive analysis of the technical watershed of industrial liquid level measurement from principles to scenarios
Working principle: Ranging is achieved by emitting sound wave pulses and receiving echoes, and calculating the time difference.
Applicable scenarios: open or closed containers (such as sewage treatment tanks) under normal pressure, normal temperature, and without strong interference
Core limitations:
Sound waves are susceptible to interference from medium density, temperature, steam, foam, etc.
The measuring range is usually ≤15 meters, and the accuracy is significantly affected by environmental fluctuations.
Working principle: Emit high-frequency electromagnetic waves (6GHz/26GHz/80GHz), and calculate the distance through changes in echo frequency
Technical advantages:
Strong microwave penetration: can penetrate dust, steam, foam (attenuation ≤30dB is still effective for measurement)
No dependence on propagation media: can work stably in vacuum to high-pressure environments
| Contrast Dimensions | Ultrasonic liquid level meter (take ABB LST200 as an example) | Radar level gauge (take Doweston DR80-G as an example) |
|---|---|---|
| Maximum range | ≤8 meters (liquid) | ≤70 meters (liquid) |
| Measuring Accuracy | ±3mm or 0.25% FS | ±1mm or 0.1% FS |
| Response Time | ≥2 seconds | ≤0.5 seconds |
| Temperature tolerance | -40°C~+85°C (heat insulation casing required) | -196°C~+450°C (direct contact with medium) |
| Stress tolerance | ≤1.6MPa | ≤16MPa |
| Installation requirements | 350mm blind area needs to be reserved | Zero blind area, can be installed against the wall |
(Data source: Doweston Laboratory Measurement Report DWS-2024-LLT003)
Scan the QR code to add a technical consultant and receive the "Ultrasonic to Radar Alternative Assessment Toolkit" for free
24-hour technical hotline:+1 (314) 325-4420
operating conditions features: Temperature 200°C+, medium containing sulfur steam
Actual measurement comparison:
Ultrasonic liquid level meter: steam causes signal attenuation, average daily error ±5.2mm
Radar level gauge: 80GHz high-frequency wave penetrates steam, and the error is stable within ±1mm
Special challenges: Dielectric constant ε<1.9, easy to form false echoes
Technical solution:
Radar level gauge enables dynamic gain algorithm, increasing signal strength by 83%
Due to the low reflectivity of the medium, the failure probability of ultrasonic liquid level gauge is as high as 67%.
Media Characteristics Diagnostics:
Dielectric constant > 1.4? Yes → Radar|No → Evaluate radar dynamic compensation capabilities
Ambient temperature screening:
>150°C or <-50°C? Yes → Radar|No → Ultrasound can be considered
Confirmation of measuring range requirements:
>15 meters? Yes → Radar|No→Go to the next link
Process control requirements:
Need a response within seconds? Yes → Radar|No → Ultrasound acceptable
Budget control dimension:
Non-critical monitoring points? Yes → Ultrasonic|No→Preferred Radar
Intelligent diagnostic system:
Automatically identify abnormal conditions such as antenna contamination and media layering
Warn equipment failures 3-6 months in advance (accuracy rate ≥92%)
Typical case: Upgrading project of a chlor-alkali chemical plant
Original system: annual maintenance cost of 12 ultrasonic level gauges is 480,000 yuan
After transformation: Using Doweston DR80-G series to achieve:
▼ Measurement stability improved by 90%
▼ Operation and maintenance costs reduced by 76%
Technical certification: Passed SIL2/ATEX/NEPSI explosion-proof certification
Scene coverage: 500+ extreme working conditions empirical case library open for query
Service commitment:
72-hour emergency response (including holidays)
Free "Liquid Level Gauge Replacement Feasibility Analysis Report"
Get exclusive plans now
Scan the QR code to add a technical consultant and receive the "Ultrasonic to Radar Alternative Assessment Toolkit" for free

Or call the 24-hour technical hotline:+1 (314) 325-4420
Further reading
"From 32 failures to zero shutdowns: Practical record of radar level gauge in LNG storage tanks"
"Industry 4.0 Era: 7 Intelligent Trends in Liquid Level Measurement"
Statement: The comparison data in this article is based on the actual measurement environment of the Doweston Innovation Center. Specific selection needs to be combined with the working conditions parameters and please consult the technical engineer for details.
Working conditions characteristics: temperature 200°C+, medium containing sulfur steam
Daily average error ±5.2mm
The error is stable within ±1mm

Tell us about your measurement task and we will help with product selection and technical questions.info@doweston.com