Blind spot distance (B) = λ x τ x C ÷ 4
Working frequency:30kHz → λ = 340m/s ÷ 30,000Hz = 11.3mm
Pulse width:τ = 1ms ( typical value )
Medium sound speed:Water medium C=1480m/s
Calculation result:B = 418mm
※ Actual installation requires an additional 20% safety margin → 418x1.2≈500mm
| parameters | Ultrasonic impact | Radar impact |
|---|---|---|
| Medium dielectric constant | ★★★Change the speed of sound directly | ★Only signal attenuation |
| Temperature fluctuations | 1.2% error per 10°C | ≤0.03%/ C (with compensation) |
| Container structure | Flange height is included in the blind zone | Only the beam angle is considered |
▪ 80GHz high frequency modulation → minimum detection 50mm
▪ FMCW frequency modulated continuous wave technology
▪ Dynamic signal filtering algorithm
Distance from tank wall < 0.3D
Echo interference +40%
Wall-mounted installation + beam angle <3°
Measurement dead zone < 10mm
▪ Media with dielectric constant ε < 2 require a still-pipe guide
▪ Ultrasonic tilt angle > 30° → blanking zone x 2-3
▪ Installation height for steam conditions ≥5xpipe diameter

Tell us about your measurement task and we will help with product selection and technical questions.info@doweston.com