Contact Us+1 (314) 325-4420 English

Tel: +1 (314) 325-4420

Service hours: Mon-Fri 9:00-17:30

Get My Quote

Global Sites Member Center
Home > Products > Level Measurement > Radar Level Meters > LRT-G1640 Series Threaded Radar Level Transmitter

LRT-G1640 Series Threaded
Radar Level Transmitter

Best seller LRT-G1640 series threaded radar level gauge Limited-time offer Liquid position m...
  • Factory Direct
    Chengdu production base, every unit calibrated before shipping
  • Fast Delivery
    Standard models in stock, custom builds on schedule
  • Technical Support
    Selection guidance / installation and commissioning / after-sales support
Brand: DOWESTONWarranty: 12 monthsOEM / customization supported

Product Overview

OVERVIEW

 Best seller 

LRT-G1640 series threaded radar level gauge   Limited-time offer 



Liquid position measurement under special general working conditions at the installation location


LRT-G1640 threaded radar level gauge is ausing the radar wave emission and reception time differenceprinciple for level measurement, withNon-contact, easy to install, wide range of measurement conditions, not affected by pressure, covering most measurement requirements. Suitable forOpen air, enclosedEtc. Liquid Level Measurement, ProductsWith display, optionalExplosion protection, 30 meter range can be set.









Features

FEATURES

The LRT-G1640 series threaded radar level meter series sensor is an 80G frequency modulated radar level measuring instrument. The flange can be installed at any angle and is easy to install. The antenna has been further optimized, and the new fast microprocessor can perform higher-speed signal analysis and processing, allowing the instrument to be used for position measurement in most working conditions.






Application: Liquid level measurement in most working conditions

Measuring range: 15, 30 meters 

Process connection: thread 

process temperature: -40~80℃( standard type ) / -40~250℃( high-temperature type )

process pressure: -0.1~0.3MPa 

Accuracy: ±2mm 

Ingress protection: IP67 

Frequency range: 80GHz 

Power supply: two-wire system (DC24V)/four-wire system (DC24V/AC220V)/six-wire system (DC12~24V)

Explosion protection: Exia IIIC T6 Ga / Exd IIC T6 Gb 

Housing: aluminum single chamber / aluminum dual chamber / plastic / stainless steel single chamber

Signal output: 4...20mA/HART (two wires/four wires) / RS485 Mod bus (six wire system)





● Compact antenna for easy installation; non-contact radar with no wear or contamination.

● Virtually unaffected by corrosion or foam; nearly immune to atmospheric water vapor, temperature and pressure changes.

● Heavy dust environments have little effect on high-frequency level meter operation.

● Shorter wavelength gives better reflection off inclined solid surfaces.

● Narrow beam angle concentrates energy, strengthening echo performance while avoiding obstructions.

● Smaller blind zone delivers good results even on small tanks.

● High signal-to-noise ratio maintains superior performance even under agitation.


Specifications

SPECIFICATIONS
Process connection Thread G1½ "A / Thread 1½ "NPT /  Flange
Antenna profileStainless steel / PTFE
HousingSeal between housing and housing coverSilicone rubber
Housing windowPolycarbonate
Ground terminalStainless Steel
Supply voltageTwo-wireStandard version(16-26) V DC
Intrinsically safe version(21.6-26.4) V DC
Power Consumptionmax 22. 5mA / 1W
Permissible ripple
Flameproof version-<100HzUss < lV
- (100-100 K) HzUss < l0mV
(22.8-26.4) V DCTwo-wire
(198-242) V AC4-wire   /  110V AC   4-wire
Cable specificationsCable entry / connectorOne M20×1.5 cable entry
One M20×1.5 blanking plug
TerminalsConductor cross-section 2.5 mm²
Output specificationsOutput Signal(4-20) mA
Communication protocolHART
Resolution 1. 6μA
Fault signalCurrent output unchanged
20. 5mA
22 mA;
3.9mA
Integration time(0-36) s, adjustable
Blind zoneAntenna tip
Measure distanceHBRD90110 meters (liquid type)
HBRD90230 meters (liquid type)
HBRD902T20 meters (liquid type)






HBRD90620 meters (liquid type)
Microwave frequency80GHz
Communication interfaceHART protocol
Measurement intervalApprox. 1 second (depending on parameter settings)
Adjustment time Approx. 1 second (depending on parameter settings)
Display resolution1mm
Operating, storage and transport temperature(-40 to 100) °C
Process temperature (at the antenna)HBRD901(-40 to 130)°C
HBRD902(-40 to 250)°C
HBRD902T(-40 to 250)°C
HBRD903(-40 to 250)°C
HBRD904(-40 to 250)°C
HBRD905(-40 to 250)°C
HBRD906(-40 to 200)°C
Relative Humidity˂ 95%
PressureMax. 4MPa
Vibration resistantMechanical vibration 10 m/s², (10-150) Hz





Downloads

DOWNLOADS
  • Brochures
  • User Manuals
  • Drawings and Software
  • PDF

    LRT-1600 Series Radar Level Meter 2024

    Simplified Chinese pdf 2024/11/01
    Download
Our experts are ready to help Wherever you are, DOWESTON's experienced engineering team is ready to support your product selection and applications - contact us today!
Contact Us→

Copyright © 2019-2026 Doweston. All rights reserved.

Copyright © 2019-2026 Doweston. All rights reserved.
DOWESTON
Back to main page
Privacy settings Privacy settings