  • Factory Direct
    Chengdu production base, every unit calibrated before shipping
  • Fast Delivery
    Standard models in stock, custom builds on schedule
  • Technical Support
    Selection guidance / installation and commissioning / after-sales support
Brand: DOWESTONWarranty: 12 monthsOEM / customization supported

Product Overview

OVERVIEW

 New 

FTM-1620H high temperatureTypeCoriolis Mass Flow Meter


CopeBadUltra high temperature 300°C+operating conditions, achieving accurate measurement of high-temperature fluid mass flow



FTM-1620H high temperature Coriolis flow meterThe mass flow meter uses a high-temperature Coriolis force transmitter and a high-temperature Coriolis force sensor structure., Proprietary flow data model algorithm, fuzzy theory control temperature and humidity algorithm,Protect itHigh precision and stability, With High temperature resistance, large measuring range, long life, suitable for harsh working conditionsFluid and gas media, Diversified information output, withThreaded, FlangedAnd other connection methods, Meet the needs of different working conditions.






Features

FEATURES

The FTM-1620F series anti-corrosion Coriolis flow meter uses the Coriolis force effect to directly measure the mass flow of the medium passing through the flow meter. It can also measure the volume flow and density of the medium and indirectly measure the temperature of the medium. It is suitable for various fields such as ingredients, filling, quantitative measurement in the food and beverage industry, ingredients to reactors in the chemical industry, aromatic hydrocarbon cracking, metering transportation of oil and gas, navigation fuel consumption measurement, pulp and paper additives, colorant addition, etc.


■ Measurement is not affected by changes in fluid density, viscosity, temperature, pressure and conductivity

■ Using special materials and processes to ensure high temperature resistance (up to 300°C)

■ There are no flow-blocking parts in the measuring pipe, no pressure loss, and low requirements for straight pipe sections. It has unique adaptability to slurry measurement. 

■ Coriolis mass flow meter directly measures mass flow and has high measurement accuracy.

■ A wide range of measurable fluids, including various liquids with high viscosity, slurries containing solids, liquids containing trace amounts of gas, and medium- and high-pressure gases with sufficient density 

■ The measured value is insensitive to fluid viscosity, and changes in fluid density have little impact on the measured value.

■ Can perform multi-parameter measurements, such as measuring density at the same time, and derive the concentration of the solute in the measurement solution from this

■ It is not sensitive to the upstream flow velocity distribution, so there is no need for upstream and downstream straight pipe sections.




 Application Areas:

■ FTM-1620F series anti-corrosion Coriolis flow meter is used to measure mass flow, volume flow, density, temperature in mining energy, steel, petroleum, chemical industry, food, medicine, electric power, industry, electric power industry, chemical industry, metallurgical industry, etc. It can also measure corrosive and toxic liquids such as acids, alkalis, and salts.




Specifications

SPECIFICATIONS


Measuring Range 3-65000 kg/h, 0.11-2390 lb/min, 3-63500 L/h
Compatible MediaAcid, alkali, salt solutions, beverages, alcohol, high viscosity liquids, highly toxic and corrosive liquids, solid-liquid two-phase slurries, non-Newtonian fluids,
Nominal DiameterDN1.5-250
Measuring Range0.25-10m/s
Zero stability0.015%FS
Zero drift0.0015%FS.PER℃
Repeatability Error  ±0.15% of measured value
Accuracy Class  0.1% FS, 0.15% FS, 0.25% FS, 0.5% FS,
Density measuring range0-4500kg/m³
Density measurement accuracy±0.002kg/ltr
Temperature measurement accuracy±0.5% of reading ±1°C
Operating Temperature-50-100°C (standard), -20-300°C (high temperature)
Working Pressure1.0-35MPa
Housing Material
Stainless steel DIN 1.4301, cast aluminum alloy
Pipe materialStainless steel DIN 1.4404
Wetted Material304, 316L, Hastelloy, titanium alloy, 316L lined with PTFE
Display  Graphic, 132×32 dots
Signal Output  4-20 mA, pulse/frequency (0.5-10000 Hz), push-pull output, programmable,
Communication output  RS-485, Modbus protocol, HART output
Power Supply  220 V AC ±15% or 24 V DC, ripple ≤5%
Electrical Connection Clamp-type terminal block
Connection Type GB flanges, internal/external threads, sanitary clamps, tri-clamp flanges, Swagelok connections
Protection Rating  IP65 (IP67 optional)
Ambient Temperature  -35 to +70°C
Relative Humidity  5%–95%
Explosion-proof MarkingFlameproof ExdIICT6
Total power consumption  Less than 15 W










Downloads

DOWNLOADS
  • Brochures
  • User Manuals
  • Drawings and Software
Our experts are ready to help Wherever you are, DOWESTON's experienced engineering team is ready to support your product selection and applications - contact us today!
Contact Us→

Copyright © 2019-2026 Doweston. All rights reserved.

Copyright © 2019-2026 Doweston. All rights reserved.
DOWESTON
Back to main page
Privacy settings Privacy settings