FTM-1620H high temperatureTypeCoriolis Mass Flow Meter
CopeBadUltra high temperature 300°C+operating conditions, achieving accurate measurement of high-temperature fluid mass flow
FTM-1620H high temperature Coriolis flow meterThe mass flow meter uses a high-temperature Coriolis force transmitter and a high-temperature Coriolis force sensor structure., Proprietary flow data model algorithm, fuzzy theory control temperature and humidity algorithm,Protect itHigh precision and stability, With High temperature resistance, large measuring range, long life, suitable for harsh working conditionsFluid and gas media, Diversified information output, withThreaded, FlangedAnd other connection methods, Meet the needs of different working conditions.
The FTM-1620F series anti-corrosion Coriolis flow meter uses the Coriolis force effect to directly measure the mass flow of the medium passing through the flow meter. It can also measure the volume flow and density of the medium and indirectly measure the temperature of the medium. It is suitable for various fields such as ingredients, filling, quantitative measurement in the food and beverage industry, ingredients to reactors in the chemical industry, aromatic hydrocarbon cracking, metering transportation of oil and gas, navigation fuel consumption measurement, pulp and paper additives, colorant addition, etc.
■ Measurement is not affected by changes in fluid density, viscosity, temperature, pressure and conductivity
■ Using special materials and processes to ensure high temperature resistance (up to 300°C)
■ There are no flow-blocking parts in the measuring pipe, no pressure loss, and low requirements for straight pipe sections. It has unique adaptability to slurry measurement.
■ Coriolis mass flow meter directly measures mass flow and has high measurement accuracy.
■ A wide range of measurable fluids, including various liquids with high viscosity, slurries containing solids, liquids containing trace amounts of gas, and medium- and high-pressure gases with sufficient density
■ The measured value is insensitive to fluid viscosity, and changes in fluid density have little impact on the measured value.
■ Can perform multi-parameter measurements, such as measuring density at the same time, and derive the concentration of the solute in the measurement solution from this
■ It is not sensitive to the upstream flow velocity distribution, so there is no need for upstream and downstream straight pipe sections.
Application Areas:
■ FTM-1620F series anti-corrosion Coriolis flow meter is used to measure mass flow, volume flow, density, temperature in mining energy, steel, petroleum, chemical industry, food, medicine, electric power, industry, electric power industry, chemical industry, metallurgical industry, etc. It can also measure corrosive and toxic liquids such as acids, alkalis, and salts.
| Measuring Range | 3-65000 kg/h, 0.11-2390 lb/min, 3-63500 L/h |
| Compatible Media | Acid, alkali, salt solutions, beverages, alcohol, high viscosity liquids, highly toxic and corrosive liquids, solid-liquid two-phase slurries, non-Newtonian fluids, |
| Nominal Diameter | DN1.5-250 |
| Measuring Range | 0.25-10m/s |
| Zero stability | 0.015%FS |
| Zero drift | 0.0015%FS.PER℃ |
| Repeatability Error | ±0.15% of measured value |
| Accuracy Class | 0.1% FS, 0.15% FS, 0.25% FS, 0.5% FS, |
| Density measuring range | 0-4500kg/m³ |
| Density measurement accuracy | ±0.002kg/ltr |
| Temperature measurement accuracy | ±0.5% of reading ±1°C |
| Operating Temperature | -50-100°C (standard), -20-300°C (high temperature) |
| Working Pressure | 1.0-35MPa |
| Housing Material | Stainless steel DIN 1.4301, cast aluminum alloy |
| Pipe material | Stainless steel DIN 1.4404 |
| Wetted Material | 304, 316L, Hastelloy, titanium alloy, 316L lined with PTFE |
| Display | Graphic, 132×32 dots |
| Signal Output | 4-20 mA, pulse/frequency (0.5-10000 Hz), push-pull output, programmable, |
| Communication output | RS-485, Modbus protocol, HART output |
| Power Supply | 220 V AC ±15% or 24 V DC, ripple ≤5% |
| Electrical Connection | Clamp-type terminal block |
| Connection Type | GB flanges, internal/external threads, sanitary clamps, tri-clamp flanges, Swagelok connections |
| Protection Rating | IP65 (IP67 optional) |
| Ambient Temperature | -35 to +70°C |
| Relative Humidity | 5%–95% |
| Explosion-proof Marking | Flameproof ExdIICT6 |
| Total power consumption | Less than 15 W |