New
FTE-1600MSeries large diameter electromagnetic flow meter
Accurately measure water flow in DN1200~2800 diameter pipes.Maintenance-free all year roundSupport bus protocol andWireless transmission
IP68 Protection rating, suitable for testing and installation in any outdoor pipeline system. It is mainly used to measure the flow of large-diameter pipelines. The flow meter displays information such as instantaneous volume, cumulative volume, instrument status, etc.!
FTE-1600M large diameter (DN) electromagnetic flow meterAn instrument that measures the volume flow of conductive liquid based on the working principle of Faraday's law of electromagnetic induction is a product of the combination of fluid mechanics and electromagnetism. We have updated the FTE-1600M large diameter electromagnetic flow meter. New breakthroughs have been made in both materials and assembly methods, as well as in the internal structure, and the rational structure has better magnetic field distribution. At the same time, a zinc spraying process has been introduced, which can protect the pipe surface of the electromagnetic flow meter for a long time even in harsh environments, and has excellent surface anti-corrosion performance.
■ Corrosion-resistant all-stainless construction, ABS injection-molded probe, simple structure
■ Solid, no moving parts, long service life, reliable measurement, strong anti-interference ability
■ The converter can be separated from the sensor for easy unified management
■ It can not only be used for general process detection, but also suitable for the measurement of pulp, paper pulp and paste liquid.
■ Using SMD devices and surface mount (SMT) technology, the circuit has high reliability;
■ The measuring range can be modified online according to the user's actual needs on site to better match the collection terminal;
■ With RS485, RS232, Hart, Modbus, Profibus-DP and other digital communication signal outputs (optional);
■ Self-test, self-diagnosis and alarm functions;
■ Ultra-low EMI switching power supply, suitable for a wide range of power supply voltage changes, and good anti-EMI performance.
Application Areas:
■ FTE-1600M large-diameter electromagnetic flow meter can measure outdoor environments that are inconvenient to observe in fields such as environmental protection, municipal management, water conservancy construction, and long-distance water delivery.
| Implementation standards | electromagnetic flow meter (JB/T 9248-2015) |
| Compatible Media | Conductive liquids and solid-liquid phases that are highly corrosive or contain impurities such as acids, alkalis, and seawater |
| Nominal Diameter | DN1200-2800 |
| Measuring Range | 0.25-10m/s |
| Flow direction | Forward, reverse, net flow |
| Turndown Ratio | 150:1 |
| Repeatability Error | ±0.1% of measured value |
| Accuracy Class | Level 0.25, Level 0.5, Level 1.0 |
| Medium temperature | 0-80℃ |
| Working Pressure | 1.0-4.0MPa (depending on pipe diameter) |
| Electrode material | Stainless steel,HastelloyGold B, Hastelloy C, Titanium |
| Uchimura material | Polyurethane, neoprene, polytetrafluoroethylene |
| Flow velocity range | 0.1-15m/s |
| Signal Output | 4-20mA (load resistance 0-750 ohms), pulse/frequency |
| Communication output | RS485, MODBUS protocol, GPRS output |
| Power Supply | 220 V AC ±15% or 24 V DC, ripple ≤5% |
| Required length of straight pipe section | Upstream ≥5DN, downstream ≥3DN, installation conditions affect the requirements of the straight pipe section |
| Connection Type | Flange connections are used between the flow meter and the piping, and the flanges comply with international standards: GB/T9119-2000 |
| Protection Rating | IP67, up to IP68 by special order |
| Ambient Temperature | -25 to +60°C |
| Relative Humidity | 5%–95% |
| Explosion-proof Marking | Flameproof ExdIICT6 |
| Total power consumption | Less than 15 W |

Tell us about your measurement task and we will help with product selection and technical questions.info@doweston.com