New
FTE-1600H high pressure electromagnetic flow meter
Extremely harsh working conditions such as high pressure and explosion-proofflow measurement
FTE-1600H high-pressure electromagnetic flow meter is composed of a high-pressure electromagnetic flow sensor produced by a special process and a high-pressure electromagnetic flow converter. It is specially used to measure flow under high-pressure conditions.Aqueous solution,Mud, cement slurry, high pressure water injectionEqually conductiveLiquid or liquid-solid two-phaseThe volume flow rate of the medium can withstand 40MPa, there are no obstructing moving parts in the pipe, there is almost no pressure loss, and the straight pipe section requirements are low.
FTE-1600H high pressure electromagnetic flow meterAn instrument that measures the volume flow of conductive liquid based on the working principle of Faraday's law of electromagnetic induction is a product of the combination of fluid mechanics and electromagnetism. We have updated the FTE-1600H high-pressure electromagnetic flow meter. New breakthroughs have been made in both materials and assembly methods, as well as in the internal structure, and the rational structure has better magnetic field distribution. At the same time, a zinc spray process has been introduced, which can protect the pipe surface of the electromagnetic flow meter for a long time even in harsh environments, and has excellent surface anti-corrosion performance.
■ Corrosion-resistant all-stainless construction, ABS injection-molded probe, simple structure
■ Solid, no moving parts, long service life, reliable measurement, strong anti-interference ability
■ Nominal pressure: 6.3, 10, 16, 25, 32, 40MPa
■ Electrode materials: molybdenum-containing stainless steel, Hastelloy B, Hastelloy C, titanium
■ It can not only be used for general process detection, but also suitable for the measurement of pulp, paper pulp and paste liquid.
■ Using SMD devices and surface mount (SMT) technology, the circuit has high reliability;
■ The measuring range can be modified online according to the user's actual needs on site to better match the collection terminal;
■ With RS485, RS232, Hart, Modbus, Profibus-DP and other digital communication signal outputs (optional);
■ Self-test, self-diagnosis and alarm functions;
■ Ultra-low EMI switching power supply, suitable for a wide range of power supply voltage changes, and good anti-EMI performance.
Application Areas:
■ FTE-1600H high-voltage electromagnetic flow meter is used to measure the flow of conductive fluids in mining energy, steel, petroleum, chemical, electric power, industry, water conservancy, and other departments. It can also measure corrosive conductive liquids such as acids, alkalis, and salts.
| Implementation standards | electromagnetic flow meter (JB/T 9248-2015) |
| Compatible Media | Conductive liquids and solid-liquid phases that are highly corrosive or contain impurities such as acids, alkalis, and seawater |
| Nominal Diameter | DN10-100 |
| Measuring Range | 0.25-10m/s |
| Flow direction | Forward, reverse, net flow |
| Turndown Ratio | 150:1 |
| Repeatability Error | ±0.1% of measured value |
| Accuracy Class | Level 0.5, Level 1.0 |
| Medium temperature | 0-80℃ |
| Working Pressure | 4.0-40MPa (depending on pipe diameter) |
| Electrode material | Molybdenum-containing stainless steel, Hastelloy B, Hastelloy C, titanium |
| Uchimura material | F46, polyurethane, screened PFE |
| Flow velocity range | 0.1-15m/s |
| Signal Output | 4-20mA (load resistance 0-750 ohms), pulse/frequency |
| Communication output | RS485, MODBUS protocol, GPRS output |
| Power Supply | 220 V AC ±15% or 24 V DC, ripple ≤5% |
| Required length of straight pipe section | Upstream ≥5DN, downstream ≥3DN, installation conditions affect the requirements of the straight pipe section |
| Connection Type | Flange connections are used between the flow meter and the piping, and the flanges comply with international standards: GB/T9119-2000 |
| Protection Rating | IP67, up to IP68 by special order |
| Ambient Temperature | -25 to +60°C |
| Relative Humidity | 5%–95% |
| Explosion-proof Marking | Flameproof ExdIICT6 |
| Total power consumption | Less than 15 W |

Tell us about your measurement task and we will help with product selection and technical questions.info@doweston.com