High-Pressure Electromagnetic Flow Meter

New FTE-1600H high pressure electromagnetic flow meter Extremely harsh working conditions su...
  • Factory Direct
    Chengdu production base, every unit calibrated before shipping
  • Fast Delivery
    Standard models in stock, custom builds on schedule
  • Technical Support
    Selection guidance / installation and commissioning / after-sales support
Brand: DOWESTONWarranty: 12 monthsOEM / customization supported

Product Overview

OVERVIEW

 New 

FTE-1600H high pressure electromagnetic flow meter 



Extremely harsh working conditions such as high pressure and explosion-proofflow measurement


FTE-1600H high-pressure electromagnetic flow meter is composed of a high-pressure electromagnetic flow sensor produced by a special process and a high-pressure electromagnetic flow converter. It is specially used to measure flow under high-pressure conditions.Aqueous solution,Mud, cement slurry, high pressure water injectionEqually conductiveLiquid or liquid-solid two-phaseThe volume flow rate of the medium can withstand 40MPa, there are no obstructing moving parts in the pipe, there is almost no pressure loss, and the straight pipe section requirements are low.





Features

FEATURES

FTE-1600H high pressure electromagnetic flow meterAn instrument that measures the volume flow of conductive liquid based on the working principle of Faraday's law of electromagnetic induction is a product of the combination of fluid mechanics and electromagnetism. We have updated the FTE-1600H high-pressure electromagnetic flow meter. New breakthroughs have been made in both materials and assembly methods, as well as in the internal structure, and the rational structure has better magnetic field distribution. At the same time, a zinc spray process has been introduced, which can protect the pipe surface of the electromagnetic flow meter for a long time even in harsh environments, and has excellent surface anti-corrosion performance.


■ Corrosion-resistant all-stainless construction, ABS injection-molded probe, simple structure

■ Solid, no moving parts, long service life, reliable measurement, strong anti-interference ability

■ Nominal pressure: 6.3, 10, 16, 25, 32, 40MPa

■ Electrode materials: molybdenum-containing stainless steel, Hastelloy B, Hastelloy C, titanium

■ It can not only be used for general process detection, but also suitable for the measurement of pulp, paper pulp and paste liquid.

■ Using SMD devices and surface mount (SMT) technology, the circuit has high reliability;

■ The measuring range can be modified online according to the user's actual needs on site to better match the collection terminal;

■ With RS485, RS232, Hart, Modbus, Profibus-DP and other digital communication signal outputs (optional);

■ Self-test, self-diagnosis and alarm functions;

■ Ultra-low EMI switching power supply, suitable for a wide range of power supply voltage changes, and good anti-EMI performance.


 Application Areas:

■ FTE-1600H high-voltage electromagnetic flow meter is used to measure the flow of conductive fluids in mining energy, steel, petroleum, chemical, electric power, industry, water conservancy, and other departments. It can also measure corrosive conductive liquids such as acids, alkalis, and salts.



Specifications

SPECIFICATIONS


Implementation standards  electromagnetic flow meter (JB/T 9248-2015)
Compatible MediaConductive liquids and solid-liquid phases that are highly corrosive or contain impurities such as acids, alkalis, and seawater
Nominal DiameterDN10-100
Measuring Range0.25-10m/s
Flow direction  Forward, reverse, net flow
Turndown Ratio  150:1
Repeatability Error  ±0.1% of measured value
Accuracy Class   Level 0.5, Level 1.0
Medium temperature0-80℃
Working Pressure4.0-40MPa (depending on pipe diameter)
Electrode materialMolybdenum-containing stainless steel, Hastelloy B, Hastelloy C, titanium
Uchimura materialF46, polyurethane, screened PFE
Flow velocity range  0.1-15m/s
Signal Output  4-20mA (load resistance 0-750 ohms), pulse/frequency
Communication output  RS485, MODBUS protocol, GPRS output
Power Supply  220 V AC ±15% or 24 V DC, ripple ≤5%
Required length of straight pipe section  Upstream ≥5DN, downstream ≥3DN, installation conditions affect the requirements of the straight pipe section
Connection Type  Flange connections are used between the flow meter and the piping, and the flanges comply with international standards: GB/T9119-2000
Protection Rating  IP67, up to IP68 by special order
Ambient Temperature  -25 to +60°C
Relative Humidity  5%–95%
Explosion-proof MarkingFlameproof ExdIICT6
Total power consumption  Less than 15 W








Downloads

DOWNLOADS
  • Brochures
  • User Manuals
  • Drawings and Software
Our experts are ready to help Wherever you are, DOWESTON's experienced engineering team is ready to support your product selection and applications - contact us today!
Contact Us→

Copyright © 2019-2026 Doweston. All rights reserved.

Copyright © 2019-2026 Doweston. All rights reserved.
DOWESTON
Back to main page
Privacy settings Privacy settings