New
TA-200A armored temperature transmitter
Applies to projectsEngineering, Boiler Equipmentetc.Medium to high temperatureIndustrial temperature measurement environment
The TA-200A armored temperature transmitter contains a thermal resistance/thermocouple temperature probe. The detection value of the probe changes with the change of temperature. The circuit in the transmitter part converts it into a linear analog output.. it hashigh accuracy, Wide measuring range, Imported thin film resistor components, reliable and stable performanceWith many advantages, cast aluminum alloy can withstand high temperature and high pressure and is suitable forElectrical industry, heating medium boiler, cooling systemTemperature measurement for most industrial automation controls.
Principle:
■ TA-200A armored temperature transmitterIt is composed of reference unit, R/V conversion unit, linear circuit, reverse connection protection, current limiting protection, V/I conversion unit, etc. After the temperature measurement thermal resistance signal is converted and amplified, the nonlinear relationship between temperature and resistance is compensated by a linear circuit. After passing through the V/I conversion circuit, a 4-20mA constant current signal that is linearly related to the measured temperature is output.
Features:
■ Wide and easy to install, multiple ranges are available, and probes of various specifications are available
■ Flexible sheathed cable with anti-vibration measuring insert
■ Good mechanical strength, vibration and shock resistant
■ low thermal inertia with minimal measurement lag
■ It has compact structure, few moving parts and wide measuring range (-200-1800°C).
■ Extremely high accuracy and repeatability, with built-in temperature compensation.
■ It is pressure-resistant, shock-proof, and moisture-resistant, and is suitable for installation and use in harsh on-site environments.
■ The thermocouple temperature transmitter has the function of automatic compensation of cold end temperature.
■ Thermal resistance, thermocouple signal input, 4-20mA or thermal resistance, thermocouple signal output
Application Areas:
■ TA-200A armored temperature transmitterIt is suitable for water treatment control equipment, electrical industry, ship hydraulic equipment, hydraulic and hydropower, chemical industry, petrochemical industry equipment and hot coal boilers, pneumatic, hydraulic, cooling system, heating system, automation engineering, etc.; the product is suitable for temperature detectors in medium and low temperature areas.
| Sensor | Thermal resistance, thermocouple |
| Measuring Range | -270-1800℃ |
| Probe length | 20-1000mm |
| Probe diameter | 3, 6 (standard), 8mm |
| Output | 0-10V, 4-20mA, thermal resistance, thermocouple |
| Accuracy | Class A, Class B |
| Repeatability | ≤0.3% FS/year |
| Error | ±0.3K+0.005XT |
| Linearity | <0.1% |
| Resolution | 0.1K |
| Temperature effect | 0.1K/10K |
| Response Time | T50,2.3S T90,5S |
| Display | Optional split display table |
| Operating Voltage | 24V DC |
| Ambient Temperature | -20-80℃ |
| Working Pressure | 4.0MPa |
| Material | Body: cast aluminum alloy |
| Probe: Stainless steel 316L (special sleeve can be customized) | |
| Display table: engineering plastics, PC | |
| Compensation cable | Silicone: Environment-50~180℃ |
| Metal mesh: Environment-20~350℃ | |
| Protection Rating | Electrical section IP67 |
| Electrical Connection | Junction box wiring |
| Electrical Protection | Reverse phase protection, overload protection, short circuit protection |
| Mounting Type | threaded connection, flange connection |
| Seal | Threaded seal, manufacturer standard |
| Accessories | Optional fire-resistant protecting tube |
| IEC international standard | ||
| Thermoelectric resistor model | Electrode material | Temperature range |
| PT10 | Platinum RTD | -200~850℃ |
| PT100 | Platinum RTD | -200~850℃ |
| PT1000 | Platinum RTD | -200~850℃ |
| Cu50 | CopperResistance | -50~150℃ |
| Cu100 | Copper RTD | -50~150℃ |
| Thermocouple index number | Cathode material | Negative electrode material | Temperature range |
| S | Platinum Rhodium 10 | Pure platinum | -50~1768.1℃ |
| R | Platinum Rhodium 13 | Pure platinum | -50~1768.1℃ |
| B | Platinum Rhodium 30 | Pure platinum 6 | 0~1820℃ |
| K | Nickel chromium | Nickel silicon | -270~1372℃ |
| T | Pure copper | Copper-nickel | -270~400℃ |
| J | Iron | Copper-nickel | -210~1200℃ |
| N | Nickel chromium silicon | Nickel silicon | -270~1300℃ |
| E | Nickel chromium | Copper-nickel | -270~1000℃ |